GitHub - hn/ginlong-solis: ESP8266 Solis to InfluxDB data logger and Solis-(75-100)K-5G-US Solis-125K-EHV-5G Solis-(185-255)K-EHV-5G-US RHI-1P(5-10)K-HVES-5G Data Logging Stick Data Logging Box Cellular Data Logger Case Study Service and Support Download Warranty After-sales Service Monitoring PV Plant Design FAQ Enterprise Explore Newsroom Video Center Event Registration About US Company Profile 2. Solar Inverters | String Inverters | Energy storage inverters - Ginlong You can learn more about what kind of cookies we use, why, and how from our Privacy policy. This video will. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Things (IOT). If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-Reorient or relocate the receiving antenna.-Increase the separation between the equipment and receiver.-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-Consult the dealer or an experienced radio/TV technician for help. Every solar system, regardless of size and complexity benefits from monitoring and this datalogger is the gateway to the informative online platform, SolisCloud. Yes my data logger also glows red as well, does appear to be a LED keepalive in the unit to show its still transmitting data to the mothership. 1. If the plant has multiple data loggers, please click View Plant. Connect the antennae to the data logger; Plug the logger into the inverter - be sure the inverter is on with at least DC power; Open the Wi-Fi settings on your phone and then search for new networks . I need a better guide to enable me to connect via an Apple Mac and PC. Ginlong Solis(Stock Code: 300763.SZ) is one of the oldest and largest global string inverter specialists, that manufactures string inverters for converting DC to AC power and interacting with utility grid, which help reduce the carbon footprint of human s Technician check pins 3 and 4 for 1.5 - 1.7 VDC, 2. I've been in contact with the team at . Note that all scripts use Python 3. Verify the RSSI (signal strength) is higher than 15%. Communication quality may be affected in lightning storms. Thanks, The Boards Team. 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Step 5: Long press the Reset button for 5 seconds until the yellow and green LEDs are quickly flashing. Press the button for 5 seconds to reset2 red lights are on and off at the same time. However, there is no guarantee that interference will not occur in a particular installation. Router signal strength is low 4. We use cookies to try and give you a better experience in Freshdesk. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Step 2: If it is a new data logger, please configure it first, then click the Willi configure. Wi-Fi trensmitting power: 802.11b/g/n: +20dBm/+18dBm/15dBm (Max) Data collection intervals: 5 minutes (adjustable:1-20 minutes) Preferences setting: Web server/Serial AT instruction. You can learn more about what kind of cookies we use, why, and how from our Privacy policy. Or directly download from APP Store or Google Play Store by searching SolisCloud. No, Modified on: Tue, Oct 4, 2022 at 2:54 PM. If you are scanning the loggers then be sure to scan the bar code on the logger itself and not the one on the inverter's spec label, see examples of the logger bar codes below: Step1: Open the datalogger shell and install the SIM caret. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . The consent submitted will only be used for data processing originating from this website. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. Let us know how can we improve this article! 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! it tries to reconnect itself vut you can just unplug it and plug it back. my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device", is it just the wifi (or has the whole system gone down) and will re-booting the system put it right. I too have recently tried to connect to the Ginlong data logger without success. 1. Shows the power supply status of the datalogger. Connect to the inverter (to get power), 3. If you are verifying the connection on m.ginlong.com or pv.ginlong.com please allow 5-10 minutes for the updates to appear. Solis monitoring system can be monitored remotely by WIFI and GPRS to provide users accurate and comprehensive data analysis and fault alarm at any time and place, this makes product operation more stable and reliable, and realize stable and intelligent operation and maintenance management services. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . If its not either move the inverter closer to the router, the router closer to the inverter or use a repeater to boost the strength. cultures. Please provide the following information as well: Ginlong Technologies Co., Ltd.No. 4G Next COnfigurate Connection 15:30 Back Enter the plant name Done Plant Name It came with a Ginlong data logger wifi stick that I have set up according to the instructions. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Solis Data Loggers Explained : Solis Solis Data Loggers. No-Grid - El inversor no reconoce la red. Go to your web browser - Input 10.10.100.254, 4. We recommend something with a larger screen. Solis inverter - Ginlong data logger - Neighbourhood | AGL 5. You can rerun the wizard and see if that works. Users can easily check device lnformatlon by logging In the monitoring center. You will have full control of your system whenever and wherever you are. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals) 2. This process can also be used to move a Solis Data Logger from one site to another. You will need to have the, Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. 5. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Once you've connected to the "AP" network, return toSolisCloudand then look for the home network that you wish to connect the logger to. 2. Solis WIFI Stick Troubleshooting TOP 5 Issues: 1. Ginlong Solis solar inverters Preamble. After you connect verify the WIFI stick sees the inverter. What do I do next? The content of the text message is . WiFi Data Logger - Solis Monitoring equipmentus - Ginlong Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. This is to (1) ensure you have the correct, password and (2) ensure there is a strong enough. Solis Data Logging Stick - Solis Australasia Plug the provided charging cable into Skyroam Solis and connect to a power source. If there are symbols in the password, it must be changed or the logger will not connect to it. With solis2influx.ino one can read out all inverter data (status and statistics) via Modbus and push it to InfluxDB. If it is set to one verify the WIFI stick has a good connection to the inverter. SolisCloud - New generation Solis PV monitoring platformuk - Ginlong Step2: Connect the datalogger to the corresponding 4-pin COM port of the inverter. Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals), 4. Then plug theWifiData Logger into the port and be sure to secure it by tightening the black connector. Otherwise, the communication quality may be affected. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. solis app gone off-line MATTYON Apr 14, 2022 hi all my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device" i wont get to it until tonight has anyone seen this before is it just the wifi (or has the whole system gone down) and will re-booting the system put it right How do you connect Solis? The [RESET] button on the back is used for the connection. Data Logging Stick: S2-WL-ST. Support WiFi and LAN communication / Plug and play, quick installation . Hi all, The AutoSave Draft feature is now disabled across the site. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Scan the bar code on the logger [note: a cellular logger is shown in the photo but it has the same scanning process as the, You should see a message that says "Bound Successfully" and now you will need to set up the logger on the local, settings and then connecting to the network that starts with "AP" - this is the. If its not broadcasting conduct this procedure - https://www.youtube.com/watch?v=nUjcDcY8-Ws - If that doesn't fix the issue of it broadcasting please contact your local Solis Service Center and RMA the WIFI Stick. Select Network, fill in the IP address assigned by the router/network administrator, 1: Connect LAN stick to operational inverter to provide power to LAN stick. Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the . Required fields are marked *. network that uses symbols in the password. first report in, so please wait until the system begins to show data on. It's probably just the datalogger that's lost connection. Note* You can use your phone, tablet or laptop. If it has a good connection to the inverter do the following steps: 1. Connect one end of an ethernet cable to LAN stickand other end directly to a computer. The replacement is working brilliantly. logger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. String Inverters | Energy storage inverters - Solisus - Ginlong Solarman Data Loggers (4-pin only) DLS-W: WiFi only data logger; DLS-L: LAN only data logger; DLS-C: 4G cellular only data logger; Solis is no longer selling these products in the US; Our distributors likely still have stock of these products but we are not promoting them; Solarman loggers do not support remote settings changes or firmware updates A Solis 5K inverter is used here as an example.Please follow the instructions below:Install the datalogger: NOTEOnly rotate the black circle, not the sliver cover. Solis GPRS/WiFi Data Logging Stickhi - Ginlong Screenshot of the Status page in the configuration interface. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. Solis Data Logger Server Information - firewall exceptions Modified on Fri, 09 Dec 2022 at 02:15 PM When the network environment of the plant has a firewall, you need to add the server information to the white list of the firewall. Solis DLS-W WIFI Stick Troubleshooting : Service Centre Solis Data Logging Box - Solis Australasia Category: Monitoring and Communication Router has a firewall blocking the data 5. Simple connectivity has your Solis solar system online in just a few steps delivering ongoing comprehensive data analysis and fault finding anytime, anywhere. Help us improve this article with your feedback. Or directly download from APP Store or Google Play Store by searching "SolisCloud". Monitoring Accessory Configured But Still Won't Link? SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering . My data logger appears to be working fine but I also notice it now glows red, appears to be a red LED inside the logger. Never lost connection since, so yeah you're probably having WiFi range issue. I have done a bit of Googling and the only negative thing I have read about the data logger is that it can lose it's wifi connection easily. Shows the connection status between the datalogger and the inverter. SolisCloud PV Monitoring Platform User Guide - Manuals+ Intro Inverter Logger Device Connect Summary Device Make Sure Phone Connected to WiFi Network Please Make Sure Phone Connected to WiFi then Click Next 15:38 Back Connect WiFi SN: 4005854756 Enter Netwo. 3: Set a manual IP for the computer using the following information -, (The IP of the computer must be with 10.10.100.XXX range to configure the LAN stick). Select Network, fill in the IP address assigned by the router/network administrator, Let us know how can we improve this article! Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. Continue with Recommended Cookies, Home solis solis S3-WIFI WiFi Stick Datalogger Installation Guide, WiFi Stick Datalogger QuickInstallation ManualVersion: 3.1. Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide Michael Allen Modified on: Tue, Oct 4, 2022 at 2:54 PM. Almost all of their products have an Modbus RS-485 interface for reading live status and statistics.. ESP8266 Solis to InfluxDB logger. i cannot connect my solar wifi data logger to my wifi but it gets Solis WiFi Data Logger Installation Guide, Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the displayed list of plants, Tap on the plant, then tap "Device" towards the top just to the right of "Overview", Tap "Datalogger" and then left-swipe the logger with your finger - you will see "Delete" in red to the right of the device, Tap "Delete" and then tap "Delete" again when asked if you want to disassociate the datalogger, "Deleted successfully" should appear - swipe down on the page to refresh it - the deleted datalogger should disappear from the device list as shown below, The deleted datalogger can now be installed on a different site/inverter, if that was the intention, A new datalogger can be installed at this site/on this inverter now that the old one has been removed.
Toronto Crime Stoppers Wanted List,
List Of Chhetri Caste In Nepal,
Articles S